MULTI
DUCTLESS INVERTER
HEAT PUMP
INSTALLATION MANUAL
Models:
MULTI18HP230V1AO
MULTI24HP230V1AO
MULTI30HP230V1AO
MULTI36HP230V1AO
MULTI42HP230V1AO
GREE ELECTRIC APPLIANCES, INC.
www.greecomfort.com
LIMITED WARRANTY
GREE distributor (hereinafter “Company”) warrants this product against failure due to defect in materials or workmanship under normal use and maintenance as
follows. All warranty periods begin on the date of original installation. If the date cannot be verified, the warranty period begins one hundred twenty (120) days from
date of manufacture. If a part fails due to defect during the applicable warranty period Company will provide a new or remanufactured part, at Company’s option,
to replace the failed defective part at no charge for the part. This limited warranty is subject to all provisions, conditions, limitations and exclusions listed below.
Seven (7) years on compressor and Five (5) years on all parts to the original registered enduser.
One (1) year warranty on remote controller unit.
Proper installation – Limited warranty applies only to systems that are installed by a state certified or licensed HVAC contractor, under applicable local and
state law in accordance with all applicable building codes and permits; GREE installation and operation instructions and good trade practices.
Warranty applies only to products remaining in their original installation location.
Defective parts must be returned to the distributor through a registered servicing dealer for credit.
LIMITATIONS OF WARRANTIES: ALL IMPLIED WARRANTIES AND/OR CONDITIONS (INCLUDING IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR USE OR PURPOSE) ARE LIMITED TO THE DURATION OF THIS LIMITED WARRANTY, SOME STATES
OR PROVINCES DO NOT ALLOW
LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY OR CONDITION LASTS, SO THE ABOVE MAY NOT APPLY TO YOU. THE EXPRESS WARRANTIES MADE IN THIS
WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON, WHATSOEVER.
THIS WARRANTY DOES NOT COVER:
1. Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts, or replacement parts,
or new units.
2. Normal maintenance as outlined in the installation and servicing instructions or Owner’s Manual, including filter cleaning and/or replacement and lubrication.
3. Failure, damage or repairs due to faulty installation, misapplication, abuse, improper servicing, unauthorized alteration or improper operation.
4. Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due to the inadequacy or interruption of electrical service.
5. Failure or damage due to floods, winds, fires, lightning, accidents, corrosive environments (rust, etc.) or other conditions beyond the control of the Company.
6. Parts not supplied or designated by Company, or damages resulting from their use.
7. Products installed outside USA and Canada.
8. Electricity or fuel costs, or increases in electricity or fuel costs from any reason whatsoever, including additional or unusual use of supplemental electric heat.
9. Any cost to replace, refill or dispose of refrigerant, including the cost of refrigerant.
10. Any special, indirect or consequential property or commercial damage of any nature whatsoever. S
ome states or provinces do not allow the exclusion of
incidental or consequential damages, so the above limitation may not apply to you.
For additional warranty exclusions, visit www.GreeComfort.com
.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.
For warranty service or repair, contact your installing contractor. You may find the installer’s name on the equipment or in your Owner’s packet.
Complete product registration below and send back by email at
service@twclimate.com
PRODUCT INFORMATION
Model No.
Serial No. Date of Installation
Owner Name
Address of Installation
Installing Contractor
Address
Phone No. / E-mail
WSO021513-DLSWARR-HP-Rev 3-8-13
Gree Electric Appliances, Inc ©2014 Cat No: DFS-MULTI-HP-1IN
TWD-0813-017 Multi install rev:Layout 1 9/27/13 12:53 PM Page 1
66129912795
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - HEAT PUMP

MULTIDUCTLESS INVERTERHEAT PUMPINSTALLATION MANUALModels:MULTI18HP230V1AOMULTI24HP230V1AOMULTI30HP230V1AOMULTI36HP230V1AOMULTI42HP230V1AOGREE ELECTRIC

Page 2 - Thank you for choosing a

INSTALLATION OF INDOOR UNITPiping Height Requirements The system piping layout must take in the constraints of vertical height on system performance.

Page 3

INSTALLATION OF INDOOR UNITPiping Height Requirements The system piping layout must take in the constraints of vertical height on system performance.

Page 4 - SAFETY PRECAUTIONS

Seal HoleHole SizeIndoor OutdoorWall Hole SleeveWall Hole DiagramINSTALLATION OF INDOOR UNITStep 4Drill Hole in Wall for Interconnecting Piping, Drain

Page 5

Seal HoleHole SizeIndoor OutdoorWall Hole SleeveWall Hole DiagramINSTALLATION OF INDOOR UNITStep 4Drill Hole in Wall for Interconnecting Piping, Drain

Page 6 - SUGGESTED TOOLS

INSTALLATION OF REFRIGERANT PIPINGStep 6Piping ConnectionsUse refrigeration grade tubing ONLY. No other type of tubing may be used. Use of other types

Page 7

INSTALLATION OF REFRIGERANT PIPINGStep 6Piping ConnectionsUse refrigeration grade tubing ONLY. No other type of tubing may be used. Use of other types

Page 8 - INSTALLATION DIMENSIONS

INSTALLATION OF REFRIGERANT PIPINGStep 6 (Cont’d)Piping and Drain Hose Connections to Indoor UnitNOTE: For maximum serviceability, it is recommended t

Page 9

INSTALLATION OF REFRIGERANT PIPINGStep 6 (Cont’d)Piping and Drain Hose Connections to Indoor UnitNOTE: For maximum serviceability, it is recommended t

Page 10 - INSTALLATION OF INDOOR UNIT

INSTALLATION OF REFRIGERANT PIPINGStep 7Piping Connections to Outdoor Unit1. Remove service valve cover (if provided) to accessthe service valves and

Page 11

INSTALLATION OF REFRIGERANT PIPINGStep 7Piping Connections to Outdoor Unit1. Remove service valve cover (if provided) to accessthe service valves and

Page 12

1 2SAFETY PRECAUTIONSPlease read the following before installation.Recognize safety information. This is the safety-alert symbol. When you see

Page 13

INSTALLATION OF POWER AND WIRING Step 8Indoor Unit Interconnecting Wire Connections Disconnect all electrical power to unit including disconnects, fus

Page 14 - OUTDOOR UNIT PREPARATION

INSTALLATION OF POWER AND WIRING Step 8Indoor Unit Interconnecting Wire Connections Disconnect all electrical power to unit including disconnects, fus

Page 15

INSTALLATION OF POWER AND WIRING Step 9 (Cont’d)6. Tightly connect main power wires to outdoor unit terminal block per wiring diagram above.7. Secure

Page 16 - Step 6 (Cont’d)

INSTALLATION OF POWER AND WIRING Step 9 (Cont’d)6. Tightly connect main power wires to outdoor unit terminal block per wiring diagram above.7. Secure

Page 17

VACUUM TESTINGStep 10Leaking TestLeak test each indoor unit, one unit at a time. Repeat the leak test sequence for each indoor unit.1. Connect the ch

Page 18 - Valve Cover

VACUUM TESTINGStep 10Leaking TestLeak test each indoor unit, one unit at a time. Repeat the leak test sequence for each indoor unit.1. Connect the ch

Page 19

25 26START-UPStep 12 Installing Photocatalytic Filter (optional)1. Lift front panel and remove air filter. (Fig. a).2. Attach photocatalytic filter

Page 20 - Interconnecting

25 26START-UPStep 12 Installing Photocatalytic Filter (optional)1. Lift front panel and remove air filter. (Fig. a).2. Attach photocatalytic filter

Page 21

Indoor Ambient Temp. Sensor F1 Short/Open of the Indoor Ambient Temperature Sensor Indoor Evaporator Temp Sensor F2 Short/Open of the Indoor Evap

Page 22 - (Reference Only)

Indoor Ambient Temp. Sensor F1 Short/Open of the Indoor Ambient Temperature Sensor Indoor Evaporator Temp Sensor F2 Short/Open of the Indoor Evap

Page 23

1 2SAFETY PRECAUTIONSPlease read the following before installation.Recognize safety information. This is the safety-alert symbol. When you see

Page 24 - Deep Vacuum Graph

APPENDIX AAuthorized Indoor Unit Combinations (Cont’d)NOMENCLATURE GUIDE42,000 BtuH Indoor Unit Size9+129+189+219+2412+1212+1812+2112+2418+1818+2118+2

Page 25

APPENDIX AAuthorized Indoor Unit Combinations (Cont’d)NOMENCLATURE GUIDE42,000 BtuH Indoor Unit Size9+129+189+219+2412+1212+1812+2112+2418+1818+2118+2

Page 26 - Fig. b Fig. c

MULTIDUCTLESS INVERTERHEAT PUMPINSTALLATION MANUALModels:MULTI18HP230V1AOMULTI24HP230V1AOMULTI30HP230V1AOMULTI36HP230V1AOMULTI42HP230V1AOGREE ELECTRIC

Page 27

4SAFETY PRECAUTIONS• The unit should be installed and serviced only by trained, qualified installers and service mechanics. Untrained personnel can p

Page 28 - 30,000 BtuH Indoor Unit Size

4SAFETY PRECAUTIONS• The unit should be installed and serviced only by trained, qualified installers and service mechanics. Untrained personnel can p

Page 29

6INSTALLATION SITE INSTRUCTIONSStep 1Installation Site of Indoor UnitSelect a site that allows for the following:• Ensure the installation complies w

Page 30 - 42,000 BtuH Indoor Unit Size

6INSTALLATION SITE INSTRUCTIONSStep 1Installation Site of Indoor UnitSelect a site that allows for the following:• Ensure the installation complies w

Page 31

7INSTALLATION DIMENSIONSIndoor unitPart Name1. Remote Controller2. Front Panel3. Air Filter4. Horizontal Louver5. Wall Hole Sleeve6. Insulation7.

Page 32

7INSTALLATION DIMENSIONSIndoor unitPart Name1. Remote Controller2. Front Panel3. Air Filter4. Horizontal Louver5. Wall Hole Sleeve6. Insulation7.